MICC Fire Survival Cable (Heavy Duty 750v) 3H

MICC Fire Survival Cable (Heavy Duty 750v) 3H

Remora Mineral Insulated Cable is a copper sheathed cable, designed to safety transmit power and control signals of critical equipment.

Standards: BS EN 60702-1:2002
Cable Type: Fire Survival Cable - Fire Resistant exceeding 3 hours @ 950°C
Temperature Range: -40°C to 250°C
Conductors: Plain Annealed Copper (Cu-ETP-2)
Insulation: Compressed Magnesium Oxide (Mg0)
Sheath: Copper (Cu-DHP)
Sheath (optional): Coloured LSZH polymer
Colour: Bare Copper, Black, Orange, Red, White

Swipe table
Code Conductors Cable Dia (mm) Weight/1km (kg) Gland size (Plain) (Earth Tail) One Hole Clip Two-Way Saddle Exc. VAT Inc. VAT
MICC3H1.5 3 8.3 265 20 20 32 342 £11.13 £13.35
MICC3H1.5-B 3 10.0 310 20 20 37 422 £12.79 £15.35
MICC3H1.5-O 3 10.0 310 20 20 37 422 £12.79 £15.35
MICC3H1.5-R 3 10.0 310 20 20 37 422 £12.79 £15.35
MICC3H1.5-W 3 10.0 310 20 20 37 422 £12.79 £15.35
MICC3H2.5 3 9.3 345 20 25 37 382 £14.09 £16.91
MICC3H2.5-B 3 11.0 390 20 25 43 462 £15.84 £19.01
MICC3H2.5-O 3 11.0 390 20 25 43 462 £15.84 £19.01
MICC3H2.5-R 3 11.0 390 20 25 43 462 £15.84 £19.01
MICC3H2.5-W 3 11.0 390 20 25 43 462 £15.84 £19.01
MICC3H4.0 3 10.4 452 20 25 40 422 £17.86 £21.43
MICC3H4-B 3 12.1 495 20 25 47 502 £19.69 £23.63
MICC3H4.0-O 3 12.1 495 20 25 47 502 £19.69 £23.63
MICC3H4-R 3 12.1 495 20 25 47 502 £19.69 £23.63
MICC3H4.0-W 3 12.1 495 20 25 47 502 £19.69 £23.63
MICC3H6.0 3 11.5 562 25 25 43 462 £23.07 £27.68
MICC3H6-B 3 13.2 602 25 25 51 542 £25.29 £30.35
MICC3H6.0-O 3 13.2 602 25 25 51 542 £25.29 £30.35
MICC3H6-R 3 13.2 602 25 25 51 542 £25.29 £30.35
MICC3H6.0-W 3 13.2 602 25 25 51 542 £25.29 £30.35
MICC3H10 3 13.6 758 25 32 54 542 Call Call Contact Us
MICC3H10-B 3 15.3 817 25 32 59 632 Call Call Contact Us
MICC3H10-O 3 15.3 817 25 32 59 632 Call Call Contact Us
MICC3H10-R 3 15.3 817 25 32 59 632 Call Call Contact Us
MICC3H10-W 3 15.3 817 25 32 59 632 Call Call Contact Us
MICC3H16 3 15.6 1039 25 40 59 632 Call Call Contact Us
MICC3H16-B 3 17.9 1130 25 40 71 752 Call Call Contact Us
MICC3H16-O 3 17.9 1130 25 40 71 752 Call Call Contact Us
MICC3H16-R 3 17.9 1130 25 40 71 752 Call Call Contact Us
MICC3H16-W 3 17.9 1130 25 40 71 752 Call Call Contact Us
MICC3H25 3 18.2 1451 40 40 71 752 Call Call Contact Us
MICC3H25-B 3 20.5 1557 40 40 79 812 Call Call Contact Us
MICC3H25-O 3 20.5 1557 40 40 79 812 Call Call Contact Us
MICC3H25-R 3 20.5 1557 40 40 79 812 Call Call Contact Us
MICC3H25-W 3 20.5 1557 40 40 79 812 Call Call Contact Us

To help improve our website we use cookies, by using this site you agree that we may store these on your device. For more information on what cookies are and why we use them please read our Cookies and Privacy Policy.